20160421_102001-2

Superior Product & Competitive Prices

ACAF® pre-engineered fire suppression systems are made up of single or multiple MxC CAF generator assemblies. This factory built assembly is sized to the number of nozzles it may supply. Larger hazardous areas can be protected by combining multiple CAF generators. CAF generators may be supplied by pressure tanks for self-contained supply systems, or a foam proportioner for a fixed water supply system. CAF generators are available in two assemblies. These modules can support 2 to 32 CAF nozzles. Our systems use lower water flow and pressure as compared to traditional foam water systems, thus our systems may be designed for applications with as much as 75 % less water demand.

PRODUCT HIGHLIGHTS

 
  • FM Approved 
  • Effectively extinguishes ignitable liquid fires in commercial, industrial and hazardous environments
  • Engineered to meet and exceed the most stringent industry standards
  • Creates a high quality finished foam from non toxic biodegradable foam from a foam water solution 
  • Pressurized Nitrogen creates CAF and powers the system

MxC CAF Generators Series

 

  • Supports one zone 
  • 2 or 4 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system

  

 
  • Supports two zones
  • 2 or 4 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system

  • Supports three zones 
  • 2 or 4 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system
 

MxC 816 CAF Generators Series

 

  • Supports one zone 
  • 8 or 16 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system
 
  • Supports two zones 
  • 8 or 16 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system

  • Supports three zones 
  • 8 or 16 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system
  •  
 
  • Supports one zones 
  • 8 or 16 CAF Nozzles per Zone ( DN-7, HDN-5 and PSN-6)
  • Optional ; 316 Stainless Steel for offshore application  
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC signal will activate the system

MxCD

  • Supports one or two zones at the same time 
  • 8,16 or  32 CAF Nozzles per MxCD   
  • Optional ; 316 Stainless Steel for Offshore Application 
  • Can work with both Fixed Water or Self Contained system 
  • When fire is detected a 24VDC Signal will activate the system

Offshore Solutions

  • Supports 1,2,3 or 4 Zones
  • 2 or 4 CAF Nozzles ( DN-7, and HDN-5) Per Zone
  • 316 Stainless Steel for Offshore Application 
  • Can work with both Fixed Water or self-contained system 
  • When fire is detected a 24VDC signal will activate the system
     
     

  • Supports 1,2,3 or 4 Zones
  • 8 or 16 CAF Nozzles ( DN-7, and HDN-5) Per Zone
  • 316 Stainless Steel for Offshore Application 
  • Can work with both Fixed Water or self-contained system 
  • When fire is detected a 24VDC signal will activate the system
     
  • Fully customizable CAF firefighting skids can support multiple zones 
  • Compact design makes maximum use of available space 
  • Pre-fabricated skids reduces labor needs on-site
  • Pre-fabrication allows for Factory Acceptance Test in its entirety
  • Constructed from corrosion resistant material to meet offshore requirements 
  • Engineered to meet EN standards

Are You Ready?

Start a New Project

What Are You Waiting for?

Let's Talk About Work